Wilkes & McLean Ltd.
(847) 534-2000
600 Estes Ave.
Schaumburg, Illinois,
USA
60193
http://www.wilkesandmclean.com
- Year Established:
- 1979
Products & Services
-
- Fluid Power Cylinders And Actuators
Web Result
- 3000 PSI Accumulators
- For other sizes and dimensions, see 3000 P.S.I.-1/5 Pt. to 40 Gal. 5000 P.S.I. - 1 Qt. to 15 Gal. 400 P.S.I. Mobile-1/2 Pt, 1 Pt., 1 Qt. Mounting Clamp Internal Design #1 Internal Design #2 Internal Design #3 Internal Design #4 Design Details: The internal designs illustrate the following construction features: The cushion cup is only used on the 11/2 gallon and larger. The oil port housing is par...
- Safety Vent
- All NACOL accumulators have a safety vent. This eliminates the possibility of accidentally removing the top cover while the accumulator is fully charged. As the top cover is un-threaded, it opens the vent hole and the nitrogen is discharged before the cover becomes a projectile. Cross section (above) illustrates nitrogen venting through safety vent as top cover opens. ...
- Cushion Cup
- To the side, is a photograph of the oil port housing removed from the accumulator. Here it is possible to see the large piece of rubber on top of the poppet, called the cushion cup. Click here to find out what causes "pinched bladders." Click here to find out why "pinched bladders" will never occur with the Nacol Design. NACOL'S Cushion Cup ...
- 5000 PSI Accumulators
- For other sizes and dimensions, see 3000 P.S.I.-1/5 Pt. to 40 Gal. 5000 P.S.I. - 1 Qt. to 15 Gal. 400 P.S.I. Mobile-1/2 Pt, 1 Pt., 1 Qt. Mounting Clamp Internal Design #2 Internal Design #3 Internal Design #4 Construction Details: The internal designs illustrate the following construction features: The cushion cup is only used on the 11/2 gallon and larger.The oil port housing is part of the accum...
- One Piece Pleated Bladder
- NACOL'S bladder is moulded in one piece. One piece construction withstands pressure better, increasing bladder life and decreasing accumulator failure. Most competitor's large accumulator bladders are made of three or four pieces that are vulcanized together. Often pin hole leaks develop at the seams, causing loss of the entire nitrogen charge. The entire bladder can even separate at these seams. ...
Website Links:
Wilkes & McLean Ltd. | 3000 PSI Accumulators | 5000 PSI Accumulators | Acrylic Coated Shell | Click here to see the... | Click here, to find out... | competition's design. | Cushion Cup | Fire Fuse | High Flow Spring | Mounting Clamp | NACOL'S spring vs. competitor's... | One Piece Pleated Bladder | Safety Vent | See small size top loading... | Top Loading | Top Loading" accumulator... | View Video | what causes "pinched... | why "pinched bladders"...