Condensing Heat Exchanger
(518) 877-8805
900 Commerce Drive
Clifton Park, New York,
USA
12065
Committed to refining and improving heat exchanger technology.
Products & Services
-
- Heat Exchangers
- Condensing
- Economizer
- Stack Emissions
- Economizer
- Smoke Stacks
- Chx
- Dew Point Barrier
- Smoke Emissions
- Industrial Emissions
- Heat Recovery
- Recovering Heat
- Teflon
- Sensible Heat
- Latent Heat
- Condensing Water
- Condensing Vapor
- Boiler Operating Efficiency
- Boiler Efficiency
-
- Flue Gas
- Incinerator Gas
- Furnace Gases
- Kiln Gases
- Exhaust Gases
- Textile Ovens
- Textile Dryers
- Boiler Steam
- Btu Recovery
- Waste Heat Recovery
- Co-generation Plants
- Waste-to-energy Plants
- Cogeneration Plants
- Waste To Energy
- Refinery Emissions
- Steam Cycle
- Steam Plant
- Boiler Plant
Web Result
- Product Description
- Product Description:History | Product Description | Applications CHX condensing heat exchangers use a single gas pass to remove both sensible and latent heat from the flue gas. The flue gas enters the heat exchanger covered with Teflon fluoropolymer through a carbon steel inlet plenum at the top and flows downward across the horizontal banks of heat exchanger tubes and exits the heat exchanger t...
- CHX System - Condensing Heat Exchanger
- The CHX System:Introduction | Eliminates Corrosion | Proven Productivity | Engineered to Perform | IFGT System | Improves Efficiency | Steam Plants | Global Warming Breaking the Dew Point Barrier Traditionally, recovering heat from exhaust gas has been economically viable only at temperatures above the acid dew point of the gas. Below this point, cold-end corrosion was inevitable, resulting in pr...
- Proven Productivity
- CHX : Proven ProductivityTotal Support | Eliminates Corrosion | Proven Productivity | Engineered to Perform | IFGT System | Improves Efficiency | Steam Plants | Global Warming Today, more than 130 CHXTM systems have improved efficiency for a wide spectrum of industries by recovering heat from boiler flue gas; incinerator, furnace and kiln exhausts, textile ovens and dryers; and other process equi...
- Condensing Heat Exchanger Corp. - Overview
- Overview:History | Product Description | Applications CHX Condensing Heat Exchangers for Flue Gas Heat Recovery covered with TEFLON fluoropolymer. Historically, boiler efficiency has been limited due to the minimum temperature allowed for the auxiliary equipment. Heat lost up the stack was in exchange for keeping the flue gas temperature above the water vapor dew point to protect the air heater ...
- Condensing Heat Exchanger Corp. - Applications for Product
- Applications:History | Product Description | Applications The most common application for a CHX condensing heat exchangers is the recovery of waste heat to preheat boiler make-up water. Preheating make-up water can increase boiler efficiency 3-5% or more. 'l'he heat recovered by a CHX condensing heat exchanger can offset much of the extraction steam required by a low pressure feedwater heater or...
Website Links: