Linear Research Associates, Inc.
(607) 387-3411
5244 Perry City Road
Trumansburg, New York,
USA
14886
Linear Research Associates provides cost-effective magnetic shielding for electron microscopy.
Products & Services
-
- Active-feedback Magnetic Shielding
- Magnetic
- Magnetic Shielding
- Active Shielding
- Shielding
- Electron Microscope
- Electron Microscopy
-
- Magnetic Shielding For Electron Microscopy
- Curt Dunnam
- Acs
- Active-compensation
- Magnetic Compensation
- Active-shield
Web Result
- MV-EMFC SYSTEMS
- MV-EMFC Systems Active-Feedback Magnetic Shielding for Electron Microscopy and MRI MV-EMFC System Types EMFC-AC-3 | EMFC-QDC-3 Installation / Domestic Pricing MV-EMFC System Components 1) Field Sensors/Preamplifiers | 2) Signal Processor/System Controller | 3) Driven Coils [ Home ] [ About LRA ] [ MV-EMFC SYSTEMS ] [ LV-EMFC R & D ] [EMFC/MRIFC Installations] [ E.M. Site A.C. Magnetic Fields A...
- E.M. Site A.C. Magnetic...
- E.M. SITEMAGNETIC FIELDS SOURCES, SURVEYS and SOLUTIONS Curt R. Dunnam Linear Research Associates, Trumansburg, NY Today Enterprises (Microscopy Today) Part 1: Introduction Part 2: ACMF/EM Antipathy Part 3: Survey Instrumentation and Methods Part 4: Survey Data Analysis Part 5: Solutions! Part 1: Introduction A decade of energetic debate regarding possible hazards of corporeal a.c. magnetic field...
- LV-EMFC R&D
- Large-Volume E.L.F. Magnetic Field Compensation [LV-EMFC] Research Project Table of Contents Page Title Page Number Introduction 1 1. Active-Negative-Feedback ACMF Shielding 1 2. Simulation Program Example 1 3. LV-EMFS Site Survey System 1 4. LV-EMFS Survey Instrument Diagram 2 5. ACMF Data Collection Using LV-EMFS System 2 6. 115 KV Right -of-Way Data Record 2 7. Fourier-Transformed Data Record 2...
- EMFC/MRIFC Installations
- EMFC/MRIFC Active-shielding Customers and Installations Boston University Philips Electronics, Eindhoven, The Netherlands University of Wisconsin, Madison, WI UOP Research Center, Des Plaines, IL Northwest University Michigan State Univeristy, East Lansing, MI NYU Medical Center, Skirball Institute, New York, NY AT&T Microelectronics (Lucent Technologies), Allentown, PA University of Texas @ H...
- Patents
- Patents U.S. Patent 5,465,012 Active Feedback System for Supression of Alternating Magnetic Fields U.S. Patent 5,469,058 Feedback Enhanced Sensor, Alternating Magnetic Field Detector Home | About LRA | MV-EMFC SYSTEMS | EMFC/MRIFC Installations LV-EMFC R&D | E.M. Site A.C. Magnetic Fields Article Patents | Hot Links | Contact LRA Copyright 1997-2012 by Linear Research Associates Designed by: S...
Website Links:
Own this business?