Rowald Refrigeration Systems, Inc.
(815) 397-7733
515 Grable St.
Rockford, Illinois,
USA
61109
rowald, refrigeration systems designers and builders of custom systems. an asme code shop
- Year Established:
- 1971
Products & Services
-
- Rowald
- Refrigeration
- Condensers
- Chillers
- Evaporators
- Water Cooled
- Air Cooled
- Dx
-
- Flooded
- Flooded-dx
- Liquid Overfeed
- Accumulators
- Oil Separators
- Receivers
- Specialty Vessels
- Demineralizer Tanks
Web Result
- Example
- contact us site map endusers Flood Evaporator cleaning This is an end view of a flooded evaporator with the head swung open. The coolant flows through the tube and the refrigerant is contained in the shell. if the tubes become fouled, they can be cleaned by running a cleaning tool through the tubes. ...
- Example 2
- contact us site map end-users WFAC-4000 40 horsepower, water-cooled chiller system used to condition air. A system was need for a manufacturing process to handle 3,800 SCFM of 40 degrees F air at -40 degrees F dew point, 5 PSI. This unit is capable of cooling air from 163 degrees F, 100% RH to 40 degrees F, 100% RH. In this cooling process, water is condensed and the removed at the air exiting end...
- Example 9
- contact us site map end-users AKI-0300 Three horsepower, air-cooled chiller used to cool water, water soluble oil, cutting oil, or hydraulic oil. The evaporator of this unit is a hybrid, not a true DX or flooded version. It is cleanable, but it requires more time for disassembly than a flooded chiller. Back to Products ...
- Refrigeration Evaporators Flooded, Direct expansion, Brazed plate, Flooded Dx
- contact us site map end-users Evaporators The evaporator section is the part of the system, which does the actual cooling of a product. It is a cold surface of proper size to cool a product to the desired temperature. There are two general types we build for liquid chilling. 1. A coil or plate type, which sits in a product that is agitated. Example 1 Example 2 Example 3 Example 4 2. A shell-and-tu...
- Example 1
- contact us site map end-users WFI-2500 25 horsepower, water-cooled, flooded chiller. 10 of these units are being used in the new addition of a compressor manufacturing plant in Tennessee. The units maintain the water and water soluble coolant at 72 degrees F. JIC electrics are standard on this unit. This type of chiller can be used to cool any fluid. It is being used to cool water, water and solub...
Website Links:
Own this business?
Request to update the information